Showing results: 16 - 30 of 49 items found.
-
HVP-40M -
PINTEK Electronics
*DC 40KV CAT II Pollution 2*600MΩ Impedance*25KV ± 2%, 40KV ± 3%*T.C. 200 ppm/oC*Positive Polarity only.*Resolution 1KV*Need not power.*CE, TUV GS, UL, CUL, IEC1010
-
I-prober 520 -
Aim-TTi
Current measurement from insulated probing of conductorSuitable for observation and measurement of current in PCB tracks, component leads and ground planesWide dynamic range of 10mA to 20A peak to peakWide bandwidth of DC to 5MHzLow noise figure equivalent to <6mA rms at full B/WSafety rated to 300V Cat II (600V Cat 1)Suitable for connection to any oscilloscopeHigh accuracy general purpose H-field probeConverts to 'closed magnetic circuit' current probe
-
782615-02 -
NI
±10 V, 100 kS/s/ch, 16-Bit, Simultaneous Input, 16-Channel C Series Voltage Input Module - The NI‑9220 performs simultaneous differential analog inputs with 250 Vrms CAT II or 60 VDC CAT I isolation. The module is capable of generating 3.2 MB/s of data at the maximum sampling rate. There are two connector options for the NI‑9220: a 36-position spring-terminal connector and a 37‑position D‑SUB connector.
-
785188-01 -
NI
±10 V, 100 kS/s/ch, 16-Bit, Simultaneous Input, 16-Channel C Series Voltage Input Module - The NI‑9220 performs simultaneous differential analog inputs with 250 Vrms CAT II or 60 VDC CAT I isolation. The module is capable of generating 3.2 MB/s of data at the maximum sampling rate. There are two connector options for the NI‑9220: a 36-position spring-terminal connector and a 37‑position D‑SUB connector.
-
782615-01 -
NI
±10 V, 100 kS/s/ch, 16-Bit, Simultaneous Input, 16-Channel C Series Voltage Input Module - The NI‑9220 performs simultaneous differential analog inputs with 250 Vrms CAT II or 60 VDC CAT I isolation. The module is capable of generating 3.2 MB/s of data at … the maximum sampling rate. There are two connector options for the NI‑9220: a 36-position spring-terminal connector and a 37‑position D‑SUB connector.
-
HVP-40 -
PINTEK Electronics
*MAX. Voltage : DC : 40KV, AC : 28KV, (50/60Hz only) CAT II.*1000MΩ Input Impedance.*Accuracy **DC: ± 1% to 20KV. ± 2% to 40KV. **AC: -5% to -10% (50/60Hz)*Division Ration : 1000:1*CE, TUV GS, UL, CUL, IEC1010
-
HH2205L -
Colluck Company Limited
High Accuracy 0.8%. Jumbo LCD display 4000 count, 22mm figure heigh. Full Auto Ranging with symbolic display. Rated CAT II 1000V. High Voltage test up to AC 750V and DC 1000V. Higher Current test up to 10A (fuse protected)
-
HVP-40DM -
PINTEK Electronics
*DC 40KV CAT II Pollution 2.*2000MΩ Impedance.*3999 LCD display.*Accuracy 1.0% full range.*T.C. 100 ppm/oC*400V/4KV/40KV, 3 range.*Resolution 0.1V/1V/10V.*PEAK HOLD, Auto power off.*CE, TUV GS, UL, CUL, IEC1010
-
HH2205K -
Colluck Company Limited
Basic Accuracy 1.0%. Jumbo LCD display 2000 count, 23.5mm figure heigh. Manual Ranging at your choice (19 Range). Rated CAT II 1000V. High Voltage test up to AC 750V and DC 1000V. Higher Current test up to 10A (fuse protected)
-
HH2099 -
Colluck Company Limited
3-1/2 digil Large LCD display 2000 count with symbolic signs. CAT II 600V rated. Basic accuracy 0.5%. Auto Ranging High Voltage test up to 600V DC and 600V AC. Higher Current test up to 1000A AC/DC. Measure Resistance up to 20MΩ
-
1942 -
Peaceful Thriving Enterprise Co Ltd
*With UKCA Approval.*Test for 230VAC circuits.*Neon indicators.*Detect faulty wiring status in 3 wire receptacle.*Various combinations of 3 neon indicators tell if wiring is OK or 6 possible faulty conditions.*Power Plug type: UK 13A socket-outlet*Measurement Category: CAT II / 1W*Frequency: 50Hz
-
72-7770 CAL -
Tenma
The 72-7770 CAL from Tenma is a palm sized digital multimeter with 3 3/4 digit LCD. It is 3 1/2digits with steady operations, fashionable design and highly reliable hand held measuring instrument. The meter measures AC/DC voltage, AC/DC current, resistance, temperature, diode and continuity. It is an ideal tool for maintenance. The multimeter features square wave output, data hold, low battery indicator and display backlight, This meter complies with the standards CE, IEC61010, in pollution degree 2, overvoltage category (CAT I 600V, CAT II 300V) and double insulation.
-
HH2002 -
Colluck Company Limited
CAT II 600V Raled. Basic Accuracy 1%. 3-3/4 digil Large LCD display 4000 count with symbolic signs. Auto Ranging High Voltage test up to 600V DC and 600V TRMS AC. Higher Current test up to 600A AC/DC. Continuity check. Measure Resistance. Measure Frequency. Measure Temperature
-
CZ2285 -
Aegis Pty. Ltd.
This lead comes standard with AS 61010 Cat II 300 V compliant banana plugs providing protection from today's telecommunications services that carry high voltages. Having been designed to meet Telstra's requirements this lead has been thoroughly tested and proven in the most harsh environments. Durability, flexibility and reliability are the primary features of this lead set.
-
72-7770 CAL DU -
Tenma
The 72-7770 CAL DU from Tenma is a palm sized digital multimeter with 3 3/4 digit LCD. It is 3 1/2digits with steady operations, fashionable design and highly reliable hand held measuring instrument. The meter measures AC/DC voltage, AC/DC current, resistance, temperature, diode and continuity. It is an ideal tool for maintenance. The multimeter features square wave output, data hold, low battery indicator and display backlight, This meter complies with the standards CE, IEC61010, in pollution degree 2, overvoltage category (CAT I 600V, CAT II 300V) and double insulation.